Important Safety InstructionsRead all warnings and instructions in this manual. Save these instructions.OperationFormula-X GC-1393GENGLow emissi
10 GC-1393F 23750-01 Formula X Dispense GunAssembly Drawings189018
11GC-1393F PartNumberDescription Qty.13867-05 O-RING 113867-07 O-RING 118383-02 BALL 120514-00 FITTING 120588-00 SEAL 120735-05 ELBOW FITTING 120796
12 GC-1393F To relieve uid and air pressures: 1. Push down Yellow slide valve, P/N 21402-00 to bleed off air to system.
13GC-1393FParts Replacement ProcedureFormula GunBefore performing maintenance on the dispense gun, follow Pressure Relief Procedure.Due to the d
14 GC-1393F4. Place PTFE washers, p/n: 23721-04 on top and bottom of uid valve, p/n: 23743-00.1. Ensure bores are clean before building mate
15GC-1393FDispense Tip Reference ChartPartNumberOrice 23047-J1 .012 J2 .014 J3 .022 M1 .012
16 GC-1393FDispense Tip Reference ChartPartNumberOriceLPA2-147-1525 0.015 1540 0.015 1550 0.015 1565
17GC-1393FTechnical DataCategory DataMaximum Fluid Working Pressure 2000 psi (14 MPa, 138 bar)Maximum Air Inlet Pressure 100 psi (0.7 MPa, 7 bar)Typic
Graco Ohio Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free fr
2 GC-1393FContentsWarnings ... 3Important Safety Information ... 5Groundi
3GC-1393FWarnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point
4 GC-1393F WARNINGSKIN INJECTION HAZARD High-pressure uid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a
5GC-1393FImportant Safety Information Methyl Ethyl Ketone Peroxide (MEKP) MEKP is among the more hazardous materials found in commerc
6 GC-1393F This equipment needs to be grounded. Ground the dispense gun through connection to a GlasCraft approved grounded uid sup
7GC-1393F Hose Attachment 1. Push in and rotate the trigger lock to stop the trigger from being activated. 2. Attach the (black
8 GC-1393FRepair KitsPartNumberDescription23792-00 GUN AIR KIT23793-00 GUN SEAL KIT23732-00 GUN FLUID VALVE KITStandard EquipmentPartNumberDescription
9GC-1393F 23750-01 Formula X Dispense GunAssembly Drawings
Comments to this Manuals